Product introduction

The series of products in the design is more advanced, in the material, structure and process has been greatly improved and improved. The high and low pressure clamps are tightened with copper draw bands or upper and side beams to form a strong frame structure, which enhances the clamping force of the iron core and the ability to withstand transportation impact. Strong short-circuit resistance, beautiful appearance selection, reliable operation, low loss, low noise, to the advanced level of similar foreign products.


S11 type 35kV oil-immersed power transformer

(50kVA~1600kVA three-phase double-winding non-exciting voltage regulation distribution transformer)


Rated capacity (kVA)

Voltage combination

Join group label

No-load loss(W)

Load

loss

(W)

No-load

current  (%)

Short circuit

impedance  (%)

high pressure

(kV)

High pressure tap range(%)

Low pressure

(kV)

50

35

38.5

±5±2×2.5%

0.4

Dyn11YynO

130

1200/1140

1.30

6.5

100

185

2010/1910

1.10

6.5

125

215

2370/2260

1.10

6.5

160

225

2820/2680

1.00

6.5

200

270

3320/3160

1.00

6.5

250

320

3950/3760

0.95

6.5

315

385

4750/4530

0.95

6.5

400

465

5740/5470

0.85

6.5

500

545

6910/6580

0.85

6.5

630

665

7860

0.65

6.5

800

785

9400

0.65

6.5

1000

920

11500

0.65

6.5

1250

1120

13900

0.60

6.5

1600

1350

16600

0.60

6.5

2000

1590

19700

0.55

6.5

2500

1890

23200

0.55

6.5

Note:

1. For transformers with a rated capacity of 500kVA and below, the negative loss value above the slash line in the table applies to the Dyn11 connection group, and the load loss value below the slash line applies to the Yyn0 connection group

2. According to user needs, can provide high pressure tap range of earth 2×2.5% transformer


S11 type 35kV oil-immersed power transformer

(630kVA~31500kVA three-phase double winding group non-exciting voltage regulation power transformer)

Rated capacity (kVA)

Voltage combination

Join group label

No-load loss(W)

Load loss

(W)

No-load

current  (%)

Short circuit

impedance  (%)

high pressure

(kV)

High pressure tap range(%)

Low pressure

(kV)

630




35




±5%

3.15

6.3

10.5







Yd11

830

7870

1.10

6.5

800

980

9410

1.00

6.5

1000

1150

11540

1.00

6.5

1250

1410

13940

0.90

6.5

1600

1700

16670

0.80

6.5

2000

2180

18380

0.70

6.5

2500

2560

19670

0.60

6.5

3150


35~38.5


±5%

3.15

6.3

10.5

3040

23090

0.56

7.0

4000

3620

27360

0.56

7.0

5000

4320

31380

0.48

7.0

6300

5250

35060

0.48

7.0

8000




35~38.5




±2×2.5%

3.15

3.3

6.3

6.6

1.05

11




Yd11

7200

38480

0.42

7.5

10000

8700

45320

0.42

7.5

12500

10080

53870

0.40

8.0

16000

12160

65840

0.40

8.0

20000

14400

79520

0.40

8.0

25000

17020

94050

0.32

8.0

31500

20220

112860

0.32

8.0

Note 1: The dimensions are designed according to the specific needs of users


S13 type 35kv oil-immersed power transformer

Rated capacity (kVA)

Voltage combination

Vector Group

Symbol

No-load loss(W)

Load

loss

(W)

No-load

current  (%)

Short circuit

impedance  (%)

high pressure

(kV)

High pressure tap range(%)

Low pressure

(kV)

50

35

38.5

±5%±2×2.5%

0.4

Dyn11

Yyn0

130

1200/1140

1.30

6.5

100

185

2010/1910

1.10

6.5

125

215

2370/2260

1.10

6.5

160

225

2820/2680

1.00

6.5

200

270

3320/3160

1.00

6.5

250

320

3950/3760

0.95

6.5

315

385

4750/4530

0.95

6.5

400

465

5740/5470

0.85

6.5

500

545

6910/6580

0.85

6.5

630

665

7860

0.65

6.5

800

785

9400

0.65

6.5

1000

920

11500

0.65

6.5

1250

1120

13900

0.60

6.5

1600

1350

16600

0.60

6.5

Note :1. According to the requirements of the transformer high pressure tapping range can be ±2×2.5%.

2. other capacity of the product performance parameters, determined by the user and the manufacturer.


SZ11 type 35kV on-load voltage regulating oil-immersed power transformer (2000KVA-20000KVA on-load voltage regulating power transformer)

Rated capacity (kVA)

Voltage combination

Join group label

No-load loss(W)

Load

loss

(W)

No-load

current  (%)

Short circuit

impedance  (%)

high pressure

(kV)

High pressure tap range(%)

Low pressure

(kV)

2000

35

±3×2.5

6.3 10.5

Ynd11

2300

19240

0.80

6.5

2500

2720

20640

0.80

6.5

3150

35~38.5

±3×2.5

6.3 10.5

3230

24710

0.72

70

4000

3870

29160

0.72

7.0

5000

4640

34200

0.68

7.0

6300

5630

36770

0.68

7.5

8000

Ynd11

7870

40610

0.60

7.5

10000

9280

480504

0.60

8.0

12500

35~38.5

±3×2.5

6.3

6.6

10.5

11

10940

56860

0.56

8.0

16000

13170

70320

0.54

8.0

20000

15570

82780

0.54

8.0



About Us

We have established a set of reasonable and orderly monitoring procedures, and under the guidance of the idea of "we pursue zero failure", we will never let a substandard product leave the factory. Seeking is our constant pursuit!

Quick Links

Product Category

Contact Us

Add: Beishou, East 2nd Ring Road, Xinhua subdistrict ofice Linqing City, Liaocheng City, Shandong Province
Phone: +86-13706350246
             +86-17588252991
             +86-15165830797   
Tel: +86-635-2557656
Copyright © 2024 Shandong Zhifeng Transformer Co., Ltd. Technology by leadong.com. Sitemap.