Availability: | |
---|---|
Quantity: | |
Characteristics of the product
one
When the power supply radius of the three-phase distribution transformer is too large, the load density is small, and the end power supply voltage is low, which affects the normal power consumption of users, the single-phase distribution transformer is installed at the end of the power supply, which can shorten the low-voltage power supply radius and solve the problem of low voltage of users.
two
When the load of the three-phase distribution transformer is too heavy, according to the load characteristics, choose the appropriate branch line to install the single-phase distribution transformer, which can transfer the load and solve the problem of capacity increase.
three
It is to install single-phase distribution transformers to supply power to residents in residential areas without three-phase power users, which can shorten the low-voltage power supply half-diameter and reduce loss.
four
It is to install single-phase distribution transformer power supply in places with low load density, wide distribution and no three-phase power users, which can save investment and solve the problem of being far away from the power point.
Installation melthod
According to user requirements, we can provide rod hanging installation structure, easy installation, and can reduce the cost of materials in the platform area
Main performance parameters
Rated Capaat (KVA) | Rated Voltage (kv) | Short-circuit impedance (%) | Connection group symbo | Non-load loss (W) | Load loss (W) | Non-load current (%) | ||
(H.V) | (LV) | |||||||
5 | 6 6.3 10 10.5 11 | 2×(0.22-0.24) 0.22-0.24 | 3.5 | 110 116 | 28 | 130 | 4.0 | |
10 | 44 | 234 | 3.5 | |||||
16 | 52 | 328 | 3.2 | |||||
20 | 64 | 387 | 3.0 | |||||
30 | 80 | 500 | 2.8 | |||||
40 | 100 | 698 | 2.5 | |||||
50 | 120 | 855 | 2.3 | |||||
63 | 144 | 1022 | 2.1 | |||||
80 | 160 | 1260 | 2.0 | |||||
100 | 192 | 1485 | 1.9 | |||||
125 | 228 | 1755 | 1.8 | |||||
160 | 292 | 2130 | 1.7 |
Characteristics of the product
one
When the power supply radius of the three-phase distribution transformer is too large, the load density is small, and the end power supply voltage is low, which affects the normal power consumption of users, the single-phase distribution transformer is installed at the end of the power supply, which can shorten the low-voltage power supply radius and solve the problem of low voltage of users.
two
When the load of the three-phase distribution transformer is too heavy, according to the load characteristics, choose the appropriate branch line to install the single-phase distribution transformer, which can transfer the load and solve the problem of capacity increase.
three
It is to install single-phase distribution transformers to supply power to residents in residential areas without three-phase power users, which can shorten the low-voltage power supply half-diameter and reduce loss.
four
It is to install single-phase distribution transformer power supply in places with low load density, wide distribution and no three-phase power users, which can save investment and solve the problem of being far away from the power point.
Installation melthod
According to user requirements, we can provide rod hanging installation structure, easy installation, and can reduce the cost of materials in the platform area
Main performance parameters
Rated Capaat (KVA) | Rated Voltage (kv) | Short-circuit impedance (%) | Connection group symbo | Non-load loss (W) | Load loss (W) | Non-load current (%) | ||
(H.V) | (LV) | |||||||
5 | 6 6.3 10 10.5 11 | 2×(0.22-0.24) 0.22-0.24 | 3.5 | 110 116 | 28 | 130 | 4.0 | |
10 | 44 | 234 | 3.5 | |||||
16 | 52 | 328 | 3.2 | |||||
20 | 64 | 387 | 3.0 | |||||
30 | 80 | 500 | 2.8 | |||||
40 | 100 | 698 | 2.5 | |||||
50 | 120 | 855 | 2.3 | |||||
63 | 144 | 1022 | 2.1 | |||||
80 | 160 | 1260 | 2.0 | |||||
100 | 192 | 1485 | 1.9 | |||||
125 | 228 | 1755 | 1.8 | |||||
160 | 292 | 2130 | 1.7 |